Calculator · NASA POWER climate data

Peak sun hours, month by month

How many hours of full sun your panels get each day — on a flat surface and at any tilt — for every month, anywhere on Earth. The number every solar sizing starts from.

Where

Loading…

Panel tilt
70°

Facing the equator. 0° = flat, 90° = vertical wall.

Loading…

What a peak sun hour is

Sunlight at noon on a clear day is close to 1,000 watts per square metre — the reference "one sun" at which panels are rated. A peak sun hour is one hour at that intensity: 1 kWh of sunlight on one square metre. A day with 4 peak sun hours delivers as much energy as four hours of full noon sun, however it is actually spread from sunrise to sunset.

That makes the arithmetic of solar power simple: 1 kWp of panels × 4 peak sun hours ≈ 4 kWh before losses — typically 3.2–3.5 kWh after temperature, wiring and inverter losses.

Why the tilted number matters

Most tables publish peak sun hours on a flat, horizontal surface. Panels are tilted, and in winter the difference is large: at 50° N a panel at 70° can receive two to three times the December sunlight of a flat one. For an off-grid system, the flat winter figure understates what a well-tilted array will make.

Peak sun hours in twenty cities

Peak sun hours per day (kWh/m² of sunlight per day), yearly average and lowest month, from NASA POWER climatology
PlaceFlat (horizontal)At best year-round tiltAt 70°Lowest month at 70°
Phoenix5.836.45 (31°)5.143.57
Los Angeles5.446.02 (31°)4.833.40
Denver4.765.51 (38°)4.773.84
Miami5.045.26 (24°)3.932.57
New York City3.934.43 (35°)3.742.89
Chicago3.804.27 (35°)3.632.64
Seattle3.483.98 (37°)3.421.83
Toronto3.644.08 (35°)3.472.10
London2.953.47 (40°)3.101.70
Dublin2.793.33 (42°)3.001.49
Berlin2.833.29 (39°)2.911.09
Warsaw2.993.49 (39°)3.091.20
Madrid4.725.31 (34°)4.423.92
Rome4.424.96 (34°)4.133.20
Stockholm2.783.42 (44°)3.140.61
Oslo2.623.26 (46°)3.020.71
Sydney4.655.14 (32°)4.183.27
Perth5.465.84 (27°)4.473.55
Cape Town5.415.90 (29°)4.643.72
Auckland4.314.73 (31°)3.873.37

From peak sun hours to system size

Array (kWp) = daily use (kWh) ÷ peak sun hours ÷ 0.8

Use the peak sun hours of your design month and your real tilt. The 0.8 is a typical performance ratio for grid-tied systems; for off-grid systems with batteries use about 0.7. The off-grid calculator does the full chain.

Questions

How are peak sun hours calculated?
Take the total solar energy that falls on a square metre in a day, in kWh/m², and read it as hours: 4.5 kWh/m² per day is 4.5 peak sun hours. The figures here come from NASA POWER monthly averages and are projected onto a tilted surface with the Hay–Davies model.
Is a peak sun hour the same as an hour of sunshine?
No. Sunshine hours count how long the sun is visible; peak sun hours measure energy. A long, hazy summer day and a short, clear winter day can have similar sunshine hours and very different peak sun hours.
How many peak sun hours do I need for solar to work?
Solar works anywhere; peak sun hours only change the size of the array. With 1.5 hours in the worst month you need about three times more panels than with 4.5 hours for the same winter output.